Corroded column bases in a portal-frame shed

Design study
A steel shed about thirty years old, where water has stood against the column bases along one side.
The columns are sound but their base plates have rusted thin. Each one is replaced with a galvanised base on a raised concrete plinth that sheds water.
The bases are replaced one at a time on temporary props, and the shed stays in use.