Taking out an internal column under a warehouse roof

A 15 m steel transfer beam along a warehouse valley line between two internal columns, with the removed column in outline. Four props on two needle beams hold the rafters of the middle frame, and fly braces tie the beam to the rafter.
Drag to turn. Right-drag to move. Click in, then scroll to zoom.Drag to turn. Two fingers to move and zoom.

Design study

A warehouse roof stands on a line of internal columns. One of them comes out to open up the floor, and a 15 metre beam takes its place.

Temporary props hold the roof while the column and the beam swap places, and the load is passed to the new beam before they come out.

The floor opens up, and the roof above never comes off.